Products Information:

The LFC Series Linear AC Power Source is integrated with the linear amplification circuit to ensure low noise and high stability. Users can easily develop programs to facilitate different applications. This linear power source provides clean power with THD less than 0.3% at 50/60Hz and it delivers wide output voltage range single phase 0-300V (opt.0-600V) ,3 phase 0-520V; frequency setting range 45-500Hz adjustable, fixed 50/60Hz.


Dongguan Sophpower Electronics Co., Ltd

  • Features
  • Specification
  • Inquiry
  • Related Product

Remote voltage feedback function to ensure the test voltage is consistent with the setting value.
Inrush current up to 5 times(3 times at 3 phase) of the peak current, allowing users to activate high inrush current loads(i.e. motor, compressor and so on).
Able to display the phase voltage per phase independently.
Real-time adjustment for the voltage& frequency instantly to save the time needed for the test.
Shortcut key lock, preventing the data from being modified due to any disoperation.
Either front panel or a remote RS-232 /485 control are available.
Precision True-RMS meter of volts, amps and power or power factor for displays and reports.
STEP and RAMP function: ideal for voltage and frequency variation tests and effectively reduces the inrush current during motor startup.




Specification

 

MODEL LFC-105 LFC-110 LFC-120 LFC-130 LFC-150
INPUT SPECIFICATIONS
Phases 1Ø2W + Ground
Voltage 220V/120V±10%(Please contact us for other voltage )
Frequency 50/60Hz±5%
OUTPUT SPECIFICATIONS
Rated Power(kVA)
0.5 1 2 3 5
Max Current 150V Range(A) 4.2 8.4 16.8 25 42
300V Range(A) 2.1 4.2 8.4 12.5 21
Phases 1Ø2W + Ground
Voltage Low Range(V) 0 - 150 V
High Range(V) 0 - 300 V
Frequency Range 50/60Hz±5%, 45-65Hz Adjustable(opt.45-400Hz)
Measurement Current(RMS)  Resolution: 1mA/10mA or 10mA/100mA Auto Range 

Accuracy: ±0.4%±0.3% F.S.±3 Counts±0.1%/100Hz
Voltage(RMS)                            Resolution: 0.1V

Accuracy: ±0.2%±0.3% F.S.±2 Counts±0.1%/100Hz
Frequency                            Resolution: 0.01Hz/0.1Hz Auto Range

                           Accuracy: ±0.1%±2 Counts±0.05%/100Hz
Total Harmonic Distortion(THD) ≤ 0.3% (Resistive Load)
Voltage Regulation ≤ 1%
Load Regulation ≤ 0.5%
Frequency Regulation
≤ 0.01%
Crest Factor  ≥ 4
Protection Over Current, Short Circuit, Over Temperature,Over Load ,Phase Deficient, Low-voltage Protection, Alarms
ENVIRONMENTAL
Operating Temperature 0° - 40° C / 32° - 104° F
Relative Humidity 10-90%,non-condensing
DISPLAYS AND CONTROLS
4 Digit LED Meters  Voltage, Current, Frequency,Power or Power factor(Optional)
Interface  RS-232 standard(opt. RS-485)
MECHANICAL SPECIFICATIONS
Dimensions(W*H*D)(mm) 520x107x480 510x195x480
Weights(Kg) 20 25 30 35 45